High-flow charging tool for efficient refrigerant charging through PortMax™ | access ports.

The NEW PortMax™ access port system is specifically designed to reduce processing time, in particular, evacuation time (degass/dehydrate) of large volume refrigerant systems currently processing through packed angle or ball valves. 

Charge Tool (CMFT70)

Ball latching connector with fixed TEE handle mechanism (eliminates pressure loading). Torques Plug to seal system. 

  • Ball latching connector without an internal valve for high flow
  • Ergonomic ball & sleeve action. Safety Latch system will not disconnect under pressure
  • 1/2 NPT media port 
Connects To:
PortMax Access Port
Max Pressure Rating:
20 Micron to 2031psi (140 bar)
Actuation Type:
OEM

PortMax™ Brochure: Click Here

PortMax™ Charge Tool Operating Instructions: Click Here

PortMax™ Charge Tool Rebuild/Repair/Seal Replace Instructions: Click Here

PortMax™ System Guide: Click Here

Configure Your Product View Maintenance Parts

Similar Products

PortMax™ | Refrigerant Access Ports

Large-capacity refrigerant access port system designed to reduce evacuation time and maximize processing flow.

PortMax™ | Leak Test Tool

High-flow tool for fast repeatable leak testing through PortMax™ | access ports.

PortMax™ | Evacuation Tool

High-flow evacuation tool for faster degassing and dehydration through PortMax™ | access ports.

PortMax™ | Service Tool

Field service tool for fast connection to PortMax™ | access ports during maintenance and recovery.

High-Flow Charging — With a Handle That Doesn’t Fight the Pressure

The FasTest PortMax™ Charge Tool (CMFT70) is the charging tool of the PortMax™ system — built to charge refrigerant efficiently, at high flow, into the large-volume systems PortMax™ is designed for. Like the rest of the PortMax™ tools it connects to the large-capacity PortMax™ access port with a ball latching connector, has no internal valve, and uses a large 1/2 NPT media port, so the charge path is wide open and fast.

Where it differs from its evacuation sibling is the handle, and the difference is deliberate. The Evacuation Tool uses a sliding TEE handle that retracts out of the flow path — the right choice under vacuum, where conductance is everything. The Charge Tool uses a fixed TEE handle mechanism that eliminates pressure loading — the right choice for charging, which happens under pressure. “Pressure loading” is the force system pressure exerts back on the tool and its handle; a design that eliminates it means the effort to operate the tool does not climb as the system fills, and the operator is not working against the charge pressure. On a tool rated to 2031 psi (140 bar), that is a real ergonomic and safety benefit.

So the two tools express one platform tuned for two opposite conditions: the Evacuation Tool opens the widest possible path for vacuum, and the Charge Tool neutralises pressure for charging. Both keep the high-flow, no-internal-valve, large-port design that makes PortMax™ fast on large systems.

Like the other PortMax™ tools, the Charge Tool also torques the Plug into the port to seal the system after charging — so filling and sealing are handled by the same tool at the same station. A safety latch prevents disconnection under pressure, and the tool spans 20 micron of vacuum to 2031 psi (140 bar).

The Problem the FasTest PortMax™ Charge Tool Solves

Charging a large-volume refrigerant system quickly, and safely, raises problems a packed angle or ball valve does not answer well:

  • Restrictive valves slow the charge: A packed angle or ball valve is a narrow flow path. Charging a large system through it is slow — the same restriction problem that dominates evacuation.

  • Pressure loads the operator: Charging happens under pressure, and that pressure pushes back on the tool and handle. A design that does not account for it makes the tool harder to operate as the system fills.

  • An internal valve restricts flow: Any valve in the charge path lowers flow. Removing it, with a large 1/2 NPT port, keeps the charge fast.

  • Charging and sealing are two steps: If sealing needs a separate operation, it adds time. The Charge Tool torques the Plug to seal at the same station.

The FasTest PortMax™ Charge Tool answers each: no internal valve and a large 1/2 NPT port for high-flow charging, a fixed TEE handle that eliminates pressure loading so operation stays easy under pressure, and plug-torquing to seal the system when the charge is done.

Key Features 

Fixed TEE Handle Mechanism — Eliminates Pressure Loading

The fixed TEE handle mechanism is designed to eliminate pressure loading — the force that system pressure exerts back on the tool as it charges. Because the handle is not loaded by that pressure, the effort to operate the tool stays consistent whether the system is empty or full, and the operator is not fighting the charge pressure. It is the charging counterpart to the Evacuation Tool’s sliding, retracting handle: each is matched to the condition its tool works in — pressure for charging, vacuum for evacuation.

No Internal Valve — High Flow

The Charge Tool has no internal valve, so nothing in the flow path restricts the charge. Combined with the large port, that is what makes charging a large-volume system fast rather than throttled.

Large 1/2 NPT Media Port

The 1/2 NPT media port carries the refrigerant charge at high flow — the same large port the PortMax™ Evacuation Tool uses, and part of why the PortMax™ system processes large systems faster than a small service valve.

Torques the Plug to Seal the System

After charging, the tool torques the Plug into the PortMax™ port to seal the system, so charging and sealing happen with one tool at one station. (The required plug torque value should be shown on the page; see the note at the end.)

Ball Latching With a Safety Latch

A ball latching connector with an ergonomic ball & sleeve action makes the connection quick and repeatable, and a safety latch system prevents disconnection under pressure — important on a charge tool, where the system is pressurised — across a range from 20 micron of vacuum to 2031 psi (140 bar).

Technical Specifications

SpecificationDetail
Product TypeHigh-flow charging tool for large-volume refrigerant systems, via PortMax™ access ports.
Part NumberCMFT70.
Connects ToPortMax™ access port.
Pressure / Vacuum Range20 micron of vacuum to 2031 psi (140 bar).
Handle MechanismFixed TEE handle — eliminates pressure loading.
Flow DesignNo internal valve, for high flow.
Media Port1/2 NPT.
SealingTorques the Plug into the port to seal the system.
Plug Torque ValuePlug: 12-14 ft-lbs (16-19 N-m) | Dust Cap: 12-14 ft-lbs (16-19 N-m) Note: Do not exceed 14 ft-lb (19 N-m) when tightening Plug. Apply counter-torque to Access Port Seat hex when tightening Plug and Dust Cap to prevent imparting stress to brazed joints.
ConnectionBall latching connector; ergonomic ball & sleeve action.
SafetySafety latch system — will not disconnect under pressure.
Actuation TypeOEM.
System RoleOne of the PortMax™ tools — alongside the Evacuation Tool, Leak Test Tool, and Service Tool — all working with PortMax™ Refrigerant Access Ports.
DocumentationPortMax™ brochure, Charge Tool operating instructions, rebuild/repair/seal replacement instructions, and the PortMax™ System Guide.

Where the FasTest PortMax™ Charge Tool Is Used

High-Flow Charging of Large-Volume Systems

Its core use is charging refrigerant into large-volume systems — the kind PortMax™ targets, previously served by packed angle or ball valves — where a wide, unobstructed charge path fills the system faster.

Charging Under Pressure

Because the fixed TEE handle eliminates pressure loading, the tool stays easy to operate as the system fills and pressure rises. That is the condition a charge tool lives in, and the reason its handle differs from the evacuation tool’s.

Sealing After Charge

The tool torques the Plug into the port to seal the system once charged, so the charge station also closes the system — no separate sealing operation or tool.

HVAC-R and Large-System Manufacturing

PortMax™ targets larger HVAC-R and refrigerant systems — commercial and industrial air conditioning, refrigeration, and heat pumps — where large charge volumes make charging speed part of the processing-time equation.

FasTest PortMax™ Charge Tool vs. a Packed Angle / Ball Valve

 Packed Angle / Ball ValvePortMax™ Charge Tool
Charge FlowRestrictive — slow chargeHigh flow — no internal valve
Port SizeTypically smallLarge 1/2 NPT
Under PressureHandle loads with pressureFixed TEE handle eliminates pressure loading
Disconnect Under PressurePossibleSafety latch prevents it
SealingSeparate operationTorques the Plug to seal
ConnectionThread / variesBall latching, ergonomic
Pressure / VacuumVaries20 micron to 2031 psi (140 bar)

Frequently Asked Questions

Q: What is the PortMax Charge Tool?

A: It is the charging tool of the FasTest PortMax™ system, part number CMFT70. It charges refrigerant at high flow into large-volume systems through PortMax™ access ports — with no internal valve, a large 1/2 NPT port, and a fixed TEE handle that eliminates pressure loading — and then torques the Plug to seal the system.

Q: What does “eliminates pressure loading” mean?

A: Charging happens under pressure, and that pressure pushes back on the tool and its handle. The fixed TEE handle mechanism is designed so that force does not load the handle — the effort to operate the tool stays consistent as the system fills, and the operator is not working against the charge pressure. On a tool rated to 2031 psi (140 bar), that is a meaningful ergonomic and safety benefit.

Q: Does the Charge Tool have an internal valve?

A: No — deliberately. Removing the internal valve keeps the charge path unobstructed for high flow, so a large-volume system charges faster.

Q: Does the Charge Tool seal the system?

A: Yes. After charging it torques the Plug into the PortMax™ port to seal the system, so charging and sealing are done by the same tool at the same station.

Q: What is the pressure and vacuum range?

A: 20 micron of vacuum to 2031 psi (140 bar).

Q: What is the difference between the PortMax Charge Tool and the Evacuation Tool?

A: They share the high-flow PortMax™ platform but are tuned for opposite conditions. The Charge Tool (CMFT70) has a fixed TEE handle that eliminates pressure loading — right for charging, which happens under pressure. The Evacuation Tool (CMFT80) has a sliding TEE handle that retracts out of the flow path — right for evacuation, where maximum conductance under vacuum matters most. Both have no internal valve, a 1/2 NPT port, a safety latch, and both torque the Plug to seal.

Q: What is the part number?

A: CMFT70. Distributors and repeat buyers can search that part number directly for the PortMax™ Charge Tool.

Q: How is PortMax different from ZeroMax and CoreMax?

A: All three are FasTest refrigerant access systems. PortMax™ is the large-capacity, high-flow system for large-volume systems that would otherwise use packed angle or ball valves. ZeroMax™ is the zero-leak, hermetic port that replaces process stub tubes, aimed at flammable-refrigerant safety. CoreMax® is a high-flow serviceable valve core and seat. FasTest’s access-ports overview compares them.

Q: Can the Charge Tool disconnect under pressure?

A: No. The safety latch system prevents disconnection while the system is under pressure — important on a charge tool, where the system is pressurised with refrigerant.

Q: What industries use the PortMax Charge Tool?

A: HVAC-R and refrigerant systems — particularly larger commercial and industrial air conditioning, refrigeration, and heat pump systems — where large charge volumes make charging speed part of processing time.